Seite 1 - Technical Manual

Allied Vision Technologies Canada Inc. 101-3750 North Fraser Way Burnaby, BC V5J 5E9 / Canada GE4000 / GE4000CTechnical Manual70

Seite 2 - Table of Contents

GE4000 Technical Manual Page 10 Item 1: GIGABIT ETHERNET PORT This port conforms to the IEEE 802.3 1000BASE-T standard for Gigabit Ethernet over cop

Seite 3 - Legal notice

GE4000 Technical Manual Page 11 Sync Out 2 and Sync Out 3 These signals only function as outputs and can be configured as follows: Exposing Corres

Seite 4

GE4000 Technical Manual Page 12 Item 4: Mini-SMB Sync Out 1 This Mini-SMB port on the camera uses an Amphenol 903-406J-51R connector. A suitable ma

Seite 5 - Warranty

GE4000 Technical Manual Page 13 Item 7: AUXILIARY POWER PORT This port is required to provide power to the camera. This port provides threaded capti

Seite 6 - Specifications

GE4000 Technical Manual Page 14 Cleaning the Sensor DO NOT CONTACT CLEAN SENSOR UNLESS ABSOLUTELY NECESSARY. Identifying Debris Debris on the image

Seite 7 - Supported Features

GE4000 Technical Manual Page 15 Adjusting the F-mount SET SCREW3 PLCS TYPF MOUNTFRONT ASSEMBLY Figure 4. Camera Front View. THE F-MOUNT IS ADJUS

Seite 8 - Mechanical

GE4000 Technical Manual Page 16 Loosen F-MOUNT FRONT ASSEMBLY Use a 1.5mm hex wrench to loosen the 3 set screws which hold the F-mount front assembl

Seite 9 - Connections

GE4000 Technical Manual Page 17 Camera Installation Computer Interface The Prosilica GE Series cameras will work with any Gigabit Ethernet network c

Seite 10 - TRIGGER INPUT

GE4000 Technical Manual Page 18 Gigabit Ethernet Setup for Windows o Install network card in computer. o Boot the PC and cancel the “Found new Ha

Seite 11 - ISOLATED GROUND

GE4000 Technical Manual Page 19 Figure 6. Network card TCP/IP address. Figure 7. Turn off Firewall. o Return to the Gige Local Properties win

Seite 12

GE4000 Technical Manual Page 2 Table of Contents Table of Contents ...

Seite 13

GE4000 Technical Manual Page 20 Gigabit Ethernet Cabling All Gigabit Ethernet cabling and connectors should be CAT5E or CAT6 compatible. Cable leng

Seite 14 - Cleaning the Sensor

GE4000 Technical Manual Page 21 Installing GigE Viewer for Testing o The latest Viewer software can be downloaded from http://www.alliedvisiontec.c

Seite 15 - Adjusting the F-mount

GE4000 Technical Manual Page 22 System Optimization o Open the Network Connections Dialog as follows: From the Windows desktop select start, then s

Seite 16

GE4000 Technical Manual Page 23 Figure 10. Network card advanced settings. o Set Maximum Frame Size or Jumbo Frames to the maximum possible value

Seite 17 - Camera Installation

GE4000 Technical Manual Page 24 Trouble Shooting Is the camera getting power? The right LED is the camera power indicator. If unlit, check the power

Seite 18

GE4000 Technical Manual Page 25 • Camera is not listed, or flashing “Camera Unavailable”: There may be multiple NICs on your system set to the sam

Seite 19

GE4000 Technical Manual Page 26 All stats 0 while streaming. Firewall likely blocking traffic • All stats 0. Likely a firewall is blocking incomin

Seite 20

GE4000 Technical Manual Page 27 Addendum

Seite 21

GE4000 Technical Manual Page 28 GE IO Schematic VDD-3.3LOGIC TXDISO+5VMAX3221CPWRMAXIM12345678 910111213141516ENC1+V+C1-C2+C2-V-RIN ROUTINVALID

Seite 22 - System Optimization

GE4000 Technical Manual Page 29 Hirose 12-pin Trigger Schematic USER TRIGGER (5V TTL DRIVER)SYNC OUT 2ONE GROUNDRETURN IS SUFFICIENT.SYNC OUT 3

Seite 23

GE4000 Technical Manual Page 3 Legal notice For customers in the U.S.A. (FCC Compliance Information) This equipment has been tested and found to

Seite 24 - Trouble Shooting

GE4000 Technical Manual Page 30 Mini-SMB Trigger Schematic OUTRG-174 COAX CABLETRIGGER INPUTINUSERS TRIGGER CIRCUITMINI-SMBMINI-SMBSYNC OUT 1RG

Seite 25 - Ipconfig /all screenshot

GE4000 Technical Manual Page 31 Trigger Timing Diagram User Trigger Logic Trigger Exposure Readout Trigger Ready Imaging Tpd Trigger Latency In

Seite 26 - Saving camera setting file

GE4000 Technical Manual Page 32 Notes on Triggering Definitions o User Trigger is the trigger signal applied by the user. o Logic Trigger is the t

Seite 27 - Addendum

GE4000 Technical Manual Page 33 Triggering during the Readout State o For applications requiring the fastest triggering cycle time whereby the cam

Seite 28 - GE IO Schematic

GE4000 Technical Manual Page 4 Contacting Allied Vision Technologies • Technical information: http://www.alliedvisiontec.com • Support: su

Seite 29 - CABLE SIDE

GE4000 Technical Manual Page 5 Introduction The GE4000 series of cameras are sensitive, 5 frames per second, 11 megapixel, Gigabit Ethernet cameras

Seite 30 - Mini-SMB Trigger Schematic

GE4000 Technical Manual Page 6 Specifications Sensor Type Kodak KAI-11002 Sensor Shutter Type Progressive Interline Image Resolution 4008 x 2672

Seite 31 - Trigger Timing Diagram

GE4000 Technical Manual Page 7 Supported Features Imaging Modes free-running, external trigger, fixed rate, software trigger Fixed Rate Control 0

Seite 32 - Notes on Triggering

GE4000 Technical Manual Page 8 Mechanical Figure 1. GE SERIES mechanical dimensions.

Seite 33

GE4000 Technical Manual Page 9 Connections 5617432 Figure 2. GE SERIES connection diagram.