Manta Technical Manual V7.2.0
103
Camera interfaces
For all Manta models:
Test conditions
Output: external 2.4 k resistor to GND, Isolated Out Power set to 12 V.
Figure 79: Manta output switching times
Parameter and value
t
d
1 µs t
s
26 µs
t
r
1 µs t
f
21 µs
t
on
= t
d
+ t
r
2 µs t
off
= t
s
+ t
f
47 µs
(t
off
can deviate by 5 µs)
Table 39: Parameters for Manta
Note
Higher external values increase the times in the table above.
I
F
0
I
C
100%
90%
10%
t
t
0
delay time
rise time
turn-on time
storage time
fall time
turn-o time
Optocoupler output (extern