Manta Technical Manual V7.2.0
9
Introduction
continued from last page
V3.0.0
[continued]
09.06.10
[continued]
[continued]
With the new firmware 1.40 due to a bug all Manta models have only
12 bit in the data path (even if the ADC delivers 14 bit): See figure 85
and figure 86.
Due to a repaired bug in FPGA and microcontroller, the
StreamHoldCapacity changed: Manta G-032 from 49 frames to 99
frames, Manta G-125 from 12 frames to 25 frames: see chapter Manta
G-032B/C on page 29 and chapter Manta G-125B/C on page 37
RGBA24 and BGRA24 are not supported, see chapter Specifications on
page 26.
Manta board level cameras have now a cooling plate: see
–chapter Manta type A board level (PoE): dimensions on page 78
–chapter Manta type A board level (PoE): C-Mount on page 80
–chapter Manta type A board level (PoE): CS-Mount on page 82
–chapter Manta type A board level (PoE): M12-Mount on page 84
Added chapter Firmware update on page 87
V4.0.0 25.10.10 Added the information, that description of status LEDs can be found in
Manta Hardware Installation Guide, see Note on page 109
Changed file format from FM7 to FM9
Added Manta G-033B/C (sensor: Sony ICX 414) and
Manta G-504B/C (sensor: Sony ICX 655):
Manta G-033B/C on page 31
Manta G-504B/C on page 57
Spectral sensitivity on page 57.
Camera lenses on page 66
Table 48 : Image memory size (typical; see note above) on page 126
•chapter Resolution and ROI frame rates on page 129
Manta angled head models: chapter Manta W90 on page 73
V4.0.1 05.01.11 Changed tripod drawing: added dimensions of three big holes (M6 and
UNC 1/4-20) in Figure 46: Tripod dimensions on page 71.
In specifications tables color pixel formats: inserted Mono8. Added
Note, that Raw8, Raw16 displayed in some viewers means the same as
Bayer8, Bayer16: see chapter Specifications on page 26.
Changed GigE Vision V1.0 to V1.2 in all specification tables in chapter
Specifications on page 26.
to be continued on next page
Version Date Remarks
Table 1: Document history